Features
Professional Grade ProductsProfessional Grade Products
Hudson Automatic
Water Fill Valve
The Hudson WFV includesttings to connect to a 1/4 inch
poly tubing. The 1/4 inch poly tubing can be trenched over
to a standard water spigot or connected to an irrigation
system by a professional irrigation specialist.
Installing the Hudson WFV
Tools needed for installation:
• 5/32 inch drill bit
• Phillips head screwdriver
• Adjustable wrench
Parts list for the WFV System
Fill valve with quick connects installed
Slide Plate with thumbscrew and 2 bolts
• Brass Quick Connect Water Spigot Fitting
(sold separately, #07000).
1/2” to 1/4” Irrigation Conversion Kit. Allows
WFV to be connected to irrigation line. (sold
separately, #827807)
• 1/4” x 100’ Poly tubing (sold separately, #29470)
NOTE
• Easy to Install, takes only a few minutes!
• Maintains a ponds proper water level
• Plastic housing protects float
• For use with Aquascape Designs’ skimmers
Made in USA for
Aquascape, Inc.
St. Charles, IL 60174 • Brampton,ON, L6T 5V7
www.aquascapedesigns.com
Item #29469.062006
CARE AND MAINTENANCE
• Regular pond maintenance such as removing debris from the skimmer basket/net will help
the WFV operate more efficiently.
Winter preparation – The WFV will not operate during extended freezing temperatures. Simply
turn off the water supply to the unit and disconnect 1/4" tubing from the WFV. To remove
tubing from the quick connect fitting, hold in the socket on the fitting and pull tubing out.
• Float must be in a flat vertical position to work.
Skimmer Installation
1) Measure down 3" inches from the top of the
Signature and Classic series for proper hole
location. The second hole should be 1" over.
2) Drill two 5/32” holes at the locations marked.
3) Hold the WFV with slide plate assembly to the
inside of the skimmer and thread the two screws
from the outside through the holes drilled.
4) Lay the tubing through the cord relief and insert
into the quick connect fittings. For Classic series,
drill a 9/32" hole in the back wall to run the
tubing through. Leave extra tubing inside the
skimmer for adjustments. To remove tubing from
the quick connect fitting, hold in the socket on
the fitting and pull tubing out.
5) Bury the 1⁄4" poly tubing to water spigot and
connect using adaptor.
6) Adjust the WFV. Final adjustments to the fill valve
should be made while the pump is operating and
the water in the pond is at the desired level. Simply
loosen the thumbscrew and slide the unit up or
down until the valve shuts off at the desired level.
The valve will shut off 3/4"-1" from the bottom of
the valve depending on pressure. Note: There will
be a short delay in shut off the first time the valve
is used while the control chamber fills with water.
Retighten the thumbscrew.
©2006 Aquascape, Inc. • All Worldwide Rights Reserved IDD 06064588-ADI B060504
PACKAGE INCLUDES:
Fill Valve
• Slide Plate with
thumbscrew and 2 bolts
• Instructions for Use
Installation Instructions
Irrigation
Conversion Kit
(#827807)
Brass Quick Connect Water
Spigot Fitting (#07000)
1/4” x 100’
Poly Tubing
(#29470)
Water Fill
Valve with
quick connects
installed
Slide
Plate
Water in
Brass Quick
Connect (sold
separately)
Poly Tubing
Water out
Water in
Brass Quick
Connect (sold
separately)
PolyTubing
Water out
Water in
Brass Quick
Connect (sold
separately)
PolyTubing
Water out
Water in
Brass Quick
Connect (sold
separately)
Poly Tubing
Water out
Water in
Brass Quick
Connect (sold
separately)
Poly Tubing
Water out
Water in
Brass Quick
Connect (sold
separately)
Poly Tubing
Water out
4 6
2
3 5
1
Poly Tubing
Brass Quick
Connect (sold
separately)
Poly Tubing
Brass Quick
Connect (sold
separately)
Poly Tubing
Brass Quick
Connect (sold
separately)
MicroSnorkel™ Installation
1) On the outside of the MicroSnorkel™,
measure 2” down and at least 1” over for
proper location. The second hole should
be 1” over. (Picture with slide plate)
2) Drill two
of
5
/
32
” holes at the location
marked.
3) Hold the slide plate assembly to the inside
of the MicroSnorkel™ and thread the
two screws from the outside through the
holes drilled.
4) Run the tubing through the pipe dis-
charge and insert into the quick connect
fitting. To remove tubing from the quick
connect fitting, hold
in the socket and pull
the tubing out.
5) Bury the ¼” poly
tubing to water
spigot and connect
using adapter.
2
4
3
5
Poly Tubing
Brass Quick
Connect (sold
separately)
1
Page view 0
1

Summary of Contents

Page 1 - Water Fill Valve

FeaturesProfessional Grade ProductsProfessional Grade ProductsHudson Automatic Water Fill ValveThe Hudson WFV includes fittings to connect to a 1/4 inc

Comments to this Manuals

No comments